All Categories > Data Acquisition Product Line > Sample and Hold Amplifiers > Part Number SHM-50ME-C  

Part Number SHM-50ME-C, Sample and Hold Amplifiers


    Download PDF Download PDF   
    border="0" Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

40nS Acquisition Time, 0.01% Accuracy, Miniature, High Speed Sample-Hold (S/H) Amplifier, -40°C to +85°C temperature range, RoHS Compliant.




 Specifications   

Resolution

16 Bit

Number of Channels

1

Acquisition Time

40 ns

Power Consumption

0.135 W

Package Type

DIP

Input Range 1st (min)

-3.5 V

Input Range 1st (max)

3.5 V

Required Supply Voltage 1st

5 V

Required Supply Voltage 2nd

-5 V

Analog Bandwidth

100 MHz

Operating Temp. Range (min)

-40 ºC

Operating Temp. Range (max)

+100 ºC

RoHS

Yes

Status

Recommended for new design


 DOWNLOADS 

shm50.pdf