DATEL Innovation & Excellence
DATEL | 120 Forbes Blvd., Suite 125 Mansfield, MA 02048 | Phone: +1-508-964-5131 | www.datel.com
All Categories > Data Acquisition Product Line > Sample and Hold Amplifiers > Part Number SHM-50GE-C  


Part Number SHM-50GE-C, Sample and Hold Amplifiers


40nS Acquisition Time, 0.01% Accuracy, Miniature, High Speed Sample-Hold (S/H) Amplifier, -40°C to +85°C temperature range, surface mount package. RoHS Compliant.



 Specifications 

Resolution

16 Bit

Number of Channels

1

Acquisition Time

40 ns

Power Consumption

0.135 W

Package Type

SMT

Input Range 1st (min)

-3.5 V

Input Range 1st (max)

3.5 V

Required Supply Voltage 1st

5 V

Required Supply Voltage 2nd

-5 V

Analog Bandwidth

100 MHz

Operating Temp. Range (min)

-40 ºC

Operating Temp. Range (max)

+100 ºC

RoHS

Yes

Status

Recommended for new design

© DATEL is a registered trademark of DATEL, Inc.